TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Lightswillnotcome
on.
1. Lightswitchisturnedoff.
2. Lampislooseorburnedout.
3. Fuseisblownorcircuitbreakeristurned
off.
4. Daylightturn-offisineffect.
5. Incorrect circuit wiring, ifthis is anew
installation.
6. Sensorisnotaimedtowarddesiredcover-
agearea.
1. Turnlightswitchon.
2. Checklampandreplaceifburnedout.
3. Replacefuseorturncircuitbreakeron.
4. Recheckafterdark.
5. Verifywiringiscorrect.
6. Re-aimsensortocoverdesiredarea.
Lights come on in
daylight.
1. Lightcontrolmaybeinstalledinarelatively
darklocation.
2. LightcontrolisinTEST.
1. Thextureisoperatingnormallyunderthese
conditions.
2. Setcontrolswitchto1,5,or10minutes.
Lightscomeonforno
apparentreason.
1. Lightcontrolmaybesensingsmallanimals
orautomobiletrafc.
2. Rangeissettoohigh.
1. ReduceRange.Re-aimsensor.
2. ReduceRange.
Lightsstayon
continuously.
1. Thesensormaybepickingupaheatsource
like an air vent, dryer vent, or brightly
painted,heat-reectivesurface.
2. SensorisinManualOverridemode.
1. ReduceRange.Re-aimsensor.
2. Setcontrolswitchto1,5,or10minutes.
Followmanualoverrideinstructionstoreset.
Lights ash on and
off.
1. Heatorlightfromthelampsmaybeturning
thelightcontrolonandoff.
2. Heatbeingreectedfromotherobjects
maybeaffectingthesensor.
3. SensorisintheTestmode.
4. Light maybeleakingthrough theood
lampreectors
1. Repositionthelampsawayfromthesensor.
2. ReduceRange.Re-aimsensor.
3. WhileinTESTmode,lightonlystaysonfor5
seconds.
4. Makesurethemetallampprotectorsarein-
stalled.