2
598-1360-00
WIRING THE LIGHT CONTROL
WARNING: Turn power off at circuit breaker
or fuse.
MOUNT THE LIGHT CONTROL
1. Alignthelightcontrolcoverplateandcoverplate
gasket.Securewiththemountingbolt.
2. Alignthethreeslotsinthedecorativeshellwith
thelampholderpins.Pushtheshellinandthen
twistclockwisetolock.Repeatforothershell.
LockNut
Toavoidwaterdamageandelectricalshock,
keeplampholders30°belowhorizontal.
5. Adjustthelampholdersbylooseningthelock
nutsbutdonotrotatethelampholdersmorethan
180°fromthefactorysetting.Whenscrewingin
theoodlamps,donotovertighten.
Keeplampsat
least1"(25mm)
fromthesensor.
Donotallowthe
lampstoblock
thelens.
Lens
3. Pushtherubberplugrmlyintoplace.
4. Ifawetlocationjunctionboxwasnotused,
caulk the wall plate mounting surface with
siliconeweathersealant.
ShellSlot
1. Removetheexistinglightxture.
2. Installthemountingstrapasshownusingtwo
screwsthattyourjunctionbox.
3. Theplastichangercanbeusedtoholdthexture
whilewiring.Thesmallendoftheplastichanger
canbethreadedthroughtheholeinthecenter
ofthecoverplate.Thesmallendthengoesinto
oneoftheslotsonthemountingstrap.
4. Routethelightcontrol’swiresthroughthelarge
gasketholes.
5. Twistthejunctionboxwiresandxturewiresto-
getherasshown.Securewithwireconnectors.
White to WhiteBlack to Black
Junction box ground wire to green ground screw
on fixture.
Gasket
Mounting
Strap
MountingBolt
RubberPlug