Heath Zenith 9700LeD Home Safety Product User Manual


 
4
598-1360-00
Note: Whenrstturnedonwaitabout1
1
/
2
minutes
forthecircuitrytocalibrate.
*resetstoSecuritymodeatdawn.
OPERATION
Mode: On-Time Works: Day Night
Test
5Seconds x x
Security
1,5or10Minutes x
Manual
Override
Until Dawn* x
MANUAL MODE
AUTO
TEST
ON-TIME Switch at 1, 5, or
10 minutes
...backon.
1SecondOFF
then...
ManualOverridemodecanonly
be activated atnight whenthe
ON-TIMEswitchissettothe1,
5,or10minuteposition.
Flipthelightswitchoffforonesec-
ondthenbackontochangefrom
SECURITY mode to MANUAL
OVERRIDEmode.
To return toSECURITY mode,
either:
•turnthelightoffforoneminute
thenturniton,or...
•daylightwillautomaticallyreset
thelighttoSECURITYmode.
MODE SWITCHING SUMMARY
Flip light switch off
for one second then
back on*
*Ifyougetconfusedwhileswitchingmodes,turn
thepoweroffforoneminute,thenbackon.Afterthe
calibrationtimethecontrolwillbeintheSECURITY
mode.
MANUAL OVERRIDE MODE
SECURITY
MODE
SPECIFICATIONS
Range ...........................Upto70ft.(21m)[varieswith
surroundingtemperature].
SensingAngle ..............Upto180°
ElectricalLoad ..............Upto300WattMaximum
Incandescent [Up to 150
Wattmaximumeachlamp
holder]or10WattMaximum
LED(Upto5WattMaximum
eachlampholder).
BulbType ......................Upto150WattMaximum
PA R 3 8 Tu n g s t e n
Incandescentor5WattLED
model2003LEDP38-65K.
PowerRequirements ....120VAC,60Hz
OperatingModes ..........TEST, SECURITY, and
MANUALOVERRIDE
ON-Timer ......................1,5,10minutes
TestTimer .....................5Seconds
Manual
OverrideTimer ..............Until Dawn
Range ...........................Adjustable