Heat & Glo LifeStyle XLR-PLUS-PB-AU Indoor Fireplace User Manual


 
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 44
C. OptionalAccessoriesRequirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control, and module
reset switch.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
OptionalRemoteControlReceiverLocation
The control module and remote control receiver can be
accessed through the air space between the rebox front
and the lower-front nishing cover panel. The decora-
tive front and glass assembly must be removed to access
these components.
The IPI control module and the remote control receiver
are placed on the rebox bottom.
12
ElectricalInformation
A. WiringRequirements
NOTICE: This appliance must be installed by a qualied
electrician in accordance with the relevant national and
local regulations.
• Wire the appliance junction cord to 220-240 VAC. This
is required for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
220/240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: The mains supply to the appliance must have
isolation of a minimum 1/8 in. (3 mm) contact separation
in both poles.
WARNING! Risk of Injury! The gas supply shall be shut
off prior to disconnecting the electrical power and remov-
ing batteries (if installed) before proceeding with any
maintenance to the appliance.
B. IntelliFirePlus™IgnitionSystemWiring
• Wire the appliance junction cord to 220-240 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction cord to a switched cir-
cuit. Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IntelliFire Plus™ Pilot Ignition (IPI)
Wiring Diagram.
Figure12.1IntelliFirePlus™PilotIgnition(IPI)WiringDiagramwithWallSwitchorThermostat
NOTE:1. Ignition module, valve, pilot, and
wall switch operate on 6 volts. 220/240 VAC
is required at junction cord.
GRAY MODULE
FLAME
SENSE
IGNITER
RC100
(OPTIONAL REMOTE CONTROL)
GROUND
ORANGE
(PILOT)
GREEN
(MAIN)
BROWN
BLACK
RED
THERMOSTAT WIRE
ASSEMBLY / WALL
SWITCH WIRE
RC300 4.5V DC
(AAA X 3)
TO JUNCTION CORD
MODULE RESET
SWITCH
WIRE ASSEMBLY
WALL SWITCH
JUMPER WIRE
OPTIONAL
• This appliance is equipped with an IntelliFire Plus™
control valve which operates on a 6 volt system.
• For units installed in Australia, the residence’s 220/240
wall outlet to which this appliance’s power cord is con-
nected, must be wired to an in-line on/off switch. This is
required for servicing and/or resetting the control module
in the event of a control module LOCK-OUT.
• Plug the 6-volt AC power supply into the appliance junction
cord to supply power to the unit.