D. ElectricalServiceandRepair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
E.JunctionCordInformation
The junction cord is installed at the factory. Refer to Figure
12.2 and 12.3. for more information.
Note: There is an alternative access to the junction cord.
This can be accessed by removing the valve assembly. See
Figures 11.1 and 11.2.
Figure12.2.JunctionCordInformation
BLUE
BROWN
GREEN/
YELLOW
Figure12.3BlowerCircuit
240VBLOWER
JUNCTIONCORD
AUX300CE
GROUNDTERMINALTO
FIREPLACECHASSIS
COUNTRYOF
DESTINATIONPLUG
OPTIONAL
F. Blower
An optional fan and auxilliary box are available for this
appliance. Refer to instructions provided with GFK-240V
fan kit.
Use of the fan requires that the Junction cord (factory in-
stalled) be connected to 220/240 VAC service before per-
manently enclosing the heater. The service cord is found
on the right exterior side of the unit. See Figure 12.3 for
wire connection detail.