Heat & Glo LifeStyle TIARAP-BR Gas Heater User Manual


 
Page 20
August 1, 2008
Heat & Glo · Tiara Petite B · 7026-101K
4. Existing Masonry Chimney
Type C - Up & Out Installation
Type D - Hearth Mount
Figure 5.24
CHIMNEY LINER
TERMINATION
CAP
3 in. (76mm)
FLEX LINER
SHOWING TWO
25 ft. (8m)
SECTIONS OF
FLEX LINER
CO-AXIAL TO
CO-LINEAR
CONNECTOR
PIPE LENGTH
OPTIONAL
CHIMNEY LINER
TERMINATION CAP
25 ft. (8m) OF 3 in.
(76mm) FLEX LINER
THIS SECTION OF THE
CHIMNEY MUST BE
SEALED
CHIMNEY MUST BE SEALED
FROM 4 ft. (1m) SECTION TO
TERMINIATION USING A
SMOKE SHELF OR A
DAMPER*. SEAL SHOULD BE
6 in. (152mm) BELOW END OF
4 ft. (1m) AIR INTAKE
SECTION.
CO-AXIAL TO CO-LINEAR
CONNECTOR
4 ft. (1m) OF 3 in. (76mm)
FLEX LINER AIR INTAKE
SECTION
ALCOVE CLEARANCE
TO COMBUSTIBLES
MUST BE MAINTAINED.
CHIMNEY LINER
TERMINATION CAP
25 ft. (8m) OF 3 in.
(76mm) FLEX
LINER EXHAUST
SECTION
THIS SECTION OF
THE CHIMNEY MUST
BE SEALED
THE CHIMNEY MUST BE
SEALED FROM THE 4 ft. (1m)
SECTION TO TERMINATION
USING A SMOKE SHELF OR A
DAMPER. THE SEAL SHOULD
BE 6 in. (152mm) BELOW THE
END OF THE 4 ft. (1m) AIR
INTAKE SECTION.
4 ft. (1m) OF 3 in.
(152mm) FLEX LINER
AIR INTAKE SECTION
CO-AXIAL TO
CO-LINEAR
CONNECTOR
PIPE LENGTH
OPTIONAL
TERMINATION
CAP
FLASHING
4 in. (1m) FLEX
LINER
TOP ADAPTOR
RETRO
CONNECTOR
90 DEGREE
ELBOW
DIRECT
VENT PIPE
Type A & B Co-Axial to Co-Linear
*In the Commonwealth of Massachusetts, the word damper shall be
replaced with the words flue restrictor.