Heat & Glo LifeStyle TIARAP-BR Gas Heater User Manual


 
August 1, 2008
Page 11
Heat & Glo · Tiara Petite B · 7026-101K
25'
24'
22'
20'
18'
16'
14'
12'
10'
8'
6'
4'
2'
6 in. (152mm) Minimum starter pipe
30 in. (762mm) Maximum Horizontal run with no vertical pipe and with 1/4 in.
(6mm) rise per foot. Must use approved Termination Cap.
C
L
25 ft. (8m)
Maximum Vertical
2' 4' 6' 8' 10' 12' 14' 15'
Termination cap
Termination cap
Example 1
Example 2
Adjust
Intake
Damper
SLK-01TRD or an approved Termination Cap
6 ft. (2m) Minimum
Vertical Termination
VERTICAL DISTANCE
FROM APPLIANCE TO
90° ELBOW
Install Flue
Restrictor
Adjust
Intake
Damper
D. How to Use the Vent Graph E. Venting Guidelines
1. Measure the distance from the top of appliance to the
center of the 90° elbow. On the graph below, draw a
horizontal line from that measurement on the vertical
axis across until it intersects with the slanted line.
2. From the point of this intersection, draw a vertical line to
the bottom of the graph.
3. The point at which this line meets the bottom line of the
graph is the maximum length of the horizontal run.
Example 1:
If the vertical dimension from the top of the
appliance to the center of the 90° elbow is 7 ft. (2m), the
horizontal run to the outer wall ange must not exceed 9
ft.-8 in. (3m).
.
Example 2: If the vertical dimension from the top of the
appliance is 21 ft. (6m), the horizontal run to the outer wall
ange must not exceed 4 ft.-3 in. (1m).
4. Each 90° elbow is equivalent to 3 ft. (914mm) of vent
pipe and each 45° elbow is equivalent to 1 ft. (305mm)
of vent pipe, and must be subtracted from vent pipe
run. A single vertical to horizontal 90° elbow is already
calculated into the allowable 15 ft. (5m) run. Each
additional 90° elbow reduces the maximum horizontal
distance by 3 ft. (914mm).
Example: The use of three elbows would reduce the
allowable horizontal run to 9 ft. (3 - 1 = 2 elbows
x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)
Notes:
The maximum horizontal vent run is 15 ft. (5m) when the
vertical vent rise is 10 ft. (3m).
Horizontal sections require a 1/4 in. (6mm) rise for every
12 in. (305mm) of horizontal travel.
Exterior vent diameter = 6-5/8 in. (168mm); Inner vent
diameter = 4 in. (102mm).
Horizontal sections require noncombustible support every
3 ft. (914mm) , e.g. wall straps.
For any vertical termination a minimum of 6 ft. (2m)
vertical must be used.
EXCEPTIONS FOR HORIZONTAL INSTALLATIONS:
*The maximum horizontal vent run is 30 in. (762mm).
*The maximum horizontal vent run with a 45° elbow is
18 in. (457mm).
*No external minimum rise is required.
*The minimum horizontal vent run is 6 in. (152mm).
Figure 5.2
NOTE: In the Commonwealth of Mas-
sachusetts the word damper shall be
replaced with the words ue restrictor.