Figure 3. Fireplace Locations and Space
Requirements
Clearance Requirements
The top, back, and sides of the fireplace are defined
by stand-offs.
Minimum Clearances from the Fireplace to
Combustible Materials
Glass Back of Metal Ends Top of
Sides Floor Fireplace of Fireplace Fireplace Ceiling*
36 inches 0 1/2 inch 1/2 inch 4-1/2 inches 31 inches
(914 mm) (13 mm) (13 mm) (89 mm) (787 mm)
The clearance to the ceiling is measured from the top of
the unit, excluding any standoffs (see Figure 13).
The minimum clearance to a perpendicular wall extending
past the face of the fireplace is one inch (25 mm).
The metal end(s) of these fireplaces may NOT be
recessed into combustible construction.
3
Installing the
Fireplace
Step 1
Locating the
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
PIER-TVFL
ST-42TVFL
36 "
GLASS
GLASS
GLASS
36"
GLASS
GLASS
1"
36"
TOP
VIEW
*