Heat & Glo LifeStyle GRAND-XTS Boiler User Manual


 
27
Heat & Glo • Supreme-XTS, Grand-XTS • 349-901 Rev. i • 12/09
Figure 11.5 Glass Assembly
F. Glass Assembly
G. Air Shutter Setting
Optimal ame appearance is dependent on the air shutter
setting. Adjustments should be made by a qualified
technician.
Handle glass doors with care.
Inspect the gasket to ensure it is undamaged.
Inspect the glass for cracks, chips or scratches.
Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door removed,
cracked, broken or scratched.
Replace glass door assembly as a complete appliance.
WARNING
Model NG LP
Grand-XTS 1/2 in. Full Open (3/4 in.)
Supreme-XTS 3/8 in. Full Open (3/4 in.)
BOTTOM LATCH
GLASS ASSEMBLY
Removing Glass Assembly
The glass assembly fastens to the replace in four places.
Two or four of the fastening mechanisms will be spring-
loaded glass latches, depending on the model. An ex-
ample of the glass latch is shown in Figure 11.5.
Supreme-XTS
To release glass assembly, pull the two bottom spring-
loaded latches forward and allow them to retract away from
the glass assembly. Remove glass assembly by carefully
pulling the bottom side of the glass assembly out rst.
Carefully slide the glass assembly outward and downward
until the top tabs are disengaged from the slots.
Grand-XTS
To release glass assembly, pull the two bottom spring-
loaded latches forward and allow them to retract away from
the glass assembly. Slide the glass assembly outward and
downward until the top latches disengage.
Replacing Glass Assembly
Supreme-XTS
Tilt glass assembly toward fireplace and slide glass
assembly up to engage top two tabs with the corresponding
slots. Fasten the two bottom latches.
Grand-XTS
Tilt glass assembly toward replace and slide glass as-
sembly upward to engage top latches. Verify top latches are