Heat & Glo LifeStyle DAKOTA-AU Indoor Fireplace User Manual


 
Heat & Glo Lifestyle Collection • Dakota-AU• 4036-914 Rev B • 06/07 21
A. Valve Access and Service
Figure 10.1 Lift Out Doors
Figure 10.3 Loosen Refractory Retaining Strip
Figure 10.4 Remove Valve Access Panel
Figure 10.5 Remove Exterior Valve Access Panel
Figure 10.6 Connect Manometer
The gas valve can be accessed behind the cement
refractory panel on the right side of the replace.
Remove door lock screw. Lift doors out and set aside.
There is a washer under each door. Be careful not to lose
the washers.
Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
Loosen lower pressure tap screw before attaching
manometer. Start up the replace to verify the pressure
and adjust as necessary. Reverse these steps to
reassemble before log positioning.
Note: Pressure tap screws must be re-tightened.
Remove logs if access is necessary after installation is
complete. See Section 8.C. Remove logs in reverse order
of set up.
Remove grate if access is necessary after installation is
complete. (Refer to Section 8.B.)
Remove two screws on side of pilot shield and remove
shield.
Remove the inside valve access panel by lifting it up and
out.
Figure 10.2 Remove Pilot Shield
Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.
WASHER
WASHER