Heat & Glo LifeStyle CERONA-42 Indoor Fireplace User Manual


 
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. F • 04/0836
B. Facing Material
Fire Risk.
Finish all edges and fronts to clearances and
speci cations listed in manual.
• Black metal appliance front may be covered with
noncombustible material only.
Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials only up to specified
clearances on top, front and side.
Seal joints between the nished wall and appliance top
and sides using only a 300º F minimum sealant.
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
Modifying or covering grilles could cause
temperature rise and re hazard.
Finishing materials must not interfere with:
• Air ow through grilles or louvers.
Operation of louvers or doors.
Access for service.
Risk of Fire
• Non-combustible clearances MUST be
maintained.
Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-
combustible de nitions.
WARNING
WARNING
WARNING
Figure 11.4
ABC
Cerona-36
in.
49 16-3/4 43-5/8
mm
1245 425 1108
Cerona-42
in.
45-1/4 16-3/4 50-5/8
mm
1149 425 1286
Note: If using the Apollo Mantel System, the appliance must
be raised 1-1/4 in. from oor.
A
B
1 in.
(25)
C
CEILING
COMBUSTIBLE
SHEATHING
NON-COMBUSTIBLE
FACING MATERIAL
IN SHADED AREAS
FIREPLACE
ARCH OPENING
CLEARANCE
TO CEILING
MINIMUM
BOTTOM OF FIREPLACE
TO BOTTOM OF
NON-COMBUSTIBLE
FACING MATERIAL
Figure 11.3 Non-combustible Facing Material
AB
Cerona-36
in. 43-5/8 50-3/16
mm 1108 1275
Cerona-42
in. 50-5/8 54-3/8
mm 1286 1381
A
B
NON-COMBUSTIBLE
FACING MATERIAL
1 in.
(25 mm)