Heat & Glo LifeStyle BW36 Indoor Fireplace User Manual


 
WITH OUTSIDE AIR
WITH OR WITHOUT OUTSIDE AIR
WITHOUT OUTSIDE AIR
4-00 8 30491D
Figure 1
Fireplace Locations
Figure 2
Installation along a wall or an
exterior chase.
Figure 3
Corner Installation
BW36 SERIES WOODBURNING FIREPLACE
* A minimum of 1" air clearance must be
maintained between the firebox and wall.
1. FIREPLACE LOCATIONS AND SPACE REQUIREMENTS.
D. PRE-INSTALLATION PREPARATION
As a room divider.
Along a wall.
In an exterior chase or
projecting into a garage.
Across a corner.
WARNING!
DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES. EXHAUST PRODUCTS OF
GASOLINE ENGINES ARE HAZARDOUS.
DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN
FROM ATTIC SPACES, BASEMENTS OR ABOVE THE ROOF WHERE OTHER
HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR.
THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY FOR SMOKING OR FLOW
REVERSAL.
A
19
3
/4"
B
C
D
D
E
A
CAT. # A B C D E
BW36 39
5
/
8
62
1
/
4
31 13
7
/
8
44
BW36C 39
5
/
8
62
1
/
4
31 13
7
/
8
44
CAT. # A
BW36 39
5
/
8
"
BW36C 39
5
/
8
"
No one builds a better fire
CAT. # A
BW36 39
5
/
8
"
BW36C 39
5
/
8
"
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as
a room divider, installed along a wall, across a corner or use an exterior chase. See Figure 1.
Figures 2 and 3 show two typical installations assuming an outside air kit is being used. Therefore, an
allowance must be made for 90° bends. Less space is required when ducting goes directly outside without form-
ing elbows.