Heat & Glo LifeStyle 6000TR-OAK-IPI Indoor Fireplace User Manual


 
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/0622
!
B. Installing Vent Components
After determining which set of starting collars will be used
(top or rear), follow venting instructions accordingly.
Venting Out the Rear Vent
Remove the installed rear seal cap from the rear starting
collars by cutting the strap at each end. (see Figure 18).
Follow the vent configuration tables accordingly.
Remove the insulation from the REAR five inch flue, pull
the heat shield out from outside of the firebox.
WARNING: THE TOP HEAT SHIELD (INSIDE
THE FIREBOX) MUST REMAIN ATTACHED IF
THE VENT SYSTEM IS ATTACHED TO THE
REAR STARTING COLLARS. SEE FIGURE 18.
Venting Out the Top Vent
Remove the two screws in the top vent collar seal cap and
remove the top vent collar seal cap and two pieces of in-
sulation inside the top two starting collars (See Figure 18).
Remove the heat shield from inside the TOP five inch flue
from outside of the firebox.
The glass must be taken off again for positioning the logs
when the unit is finally installed in place and finished around
it. Re-install the glass door. Attach vent system to the top
starting collars.
WARNING: THE REAR VENT COLLAR SEAL
CAP MUST REMAIN ATTACHED TO THE REAR
VENT COLLARS IF THE VENT SYSTEM IS AT-
TACHED TO THE TOP STARTING COLLARS.
WARNING: FAILURE TO REMOVE INSULATION
IN THE SET OF COLLARS YOU
ARE USING
COULD CAUSE A FIRE.
WARNING: YOU MUST LEAVE THE INSULATION
IN PLACE IN THE SET OF COLLARS YOU ARE
NOT USING.
Figure 18
CUT
HERE
Venting Out Rear
Venting Out Top
!
!
!
HEAT
SHIELD
DISCARD
INSULATION
and
HEAT SHIELD
HEAT
SHIELD
INSULATION
DISCARD BOTH
PIECES and
HEAT SHIELD
SEAL
CAP
SEAL
CAP
Cut the seal cap
strap and remove white
gasket material.
1. Attach the First Vent Component to the
Starting Collars
To attach the first vent component to the starting collars of
the fireplace:
Make sure that the fiberglass gasket supplied in the
manual bag seals between the first 8 inch (203mm)
vent component and the outer fireplace wrap. Using 2
self-tapping screws from the manual bag secure that
gasket to the outer wrap (see Figure 19).
Figure 19. Fiberglass Gasket
FIRST VENT
COMPONENT
FIBERGLASS
GASKET
OUTER
WRAP
DVP PIPE:
2. Assembling Vent Sections
Refer to Cinch Pipe and Termination Cap installation in-
structions.
1. Attaching the Venting to the Fireplace
Refer to Cinch Pipe and Termination Cap installation in-
structions.
!
WARNING: ENSURE THAT THE FIBERGLASS
GASKET SUPPLIED WITH THE FIREPLACE
SEALS BETWEEN THE FIRST VENT COMPONENT
AND THE OUTER FIREPLACE WRAP.
If the installation is for a termination cap attached directly
to the fireplace, skip to the sections, Install Firestops and
Vent Termination.