Heat & Glo LifeStyle 6000TR-OAK-IPI Indoor Fireplace User Manual


 
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06
13
Framing should be
constructed of 2 X 4
lumber or heavier.
A.............. 42”*
B..........38 1/2”
C................ 22”
D..........42 3/4”
E. .........27 7/8”
Figure 3. Framing Dimensions
Step 2. Framing the Fireplace
Fireplace framing can be built before or after the fireplace is
set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.
1/2” CLEARANCE FROM BACK OF FIREPLACE TO COMBUSTIBLE
0” CLEARANCE TO
FRAMING MEMBER
0” CLEARANCE
1/2” CLEARANCE
FROM BOTH SIDES
OF FIREPLACE
TO COMBUSTIBLE
FRAMING
MEMBER
Shows center of 10” x 12” vent framing
holes for top and rear venting. The center
of the hole is one (1) inch (25.4mm) above
the center of the horizontal vent pipe.
E D
A
B
C
WALL
STUD
3 1/2”
3
Noncombustible zone is defined
by 3” above the elbow for the
entire width and depth (behind
the front header) of the firebox.