18
Heat Controller, Inc.
1900 Wellworth Avenue
Jackson, MI 49203
DRAIN EXCESS CONDENSATE WATER
10.
Condensate Disposal:
Drain Water from Upper Drain Port:
Procedures: Connect the Water Drain House to the Upper Drain Port
allowing water to flow to a water bucket. (See above illustration).
Remember to reinstall the cap on Upper Drain Port after draining water. The
Upper Drain Port can be used if a floor drain or some other means of
disposing of condensate is not available.
Drain Water from Lower Drain Port: (Before Long Term Storage Only)
Procedures: Remove the Rubber Drain Plug on Lower Drain Port.
Connect the Water Drain Hose to allow water to drain to a floor drain or other
water outlet. Remember to reinstall the Rubber Drain Plug after draining
water.
Under normal operating conditions, this unit is designed to dispose of
condensate collected via an internal system that pumps water onto the hot
condenser coil for re-evaporation. It is then expelled to the outdoors via the
air outlet hose. If the unit is operated for prolonged periods during very high
humidity conditions, this system may become overwhelmed and the unit will
shut off. Excess water must be drained from the unit before it will restart.
Lower Drain Port
Upper Drain Port