Figure 14.9 Fixed Glass Assembly
H. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate replace with glass removed, cracked,
broken or scratched.
Replace as a complete assembly.
Removing Fixed Glass Assembly
Pull the four glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 14.9).
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
I. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
Use non-combustible materials to cover the gap between
the sheet rock and the appliance (when applicable to the
model).
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)
SL-750TRSFHHIPI 3/8 in.
SL-750TRSFHHIPI (LP) Fixed
J. Air Shutter Setting
This appliance has an adjustable air shutter (which con-
trols the primary air) factory set for the minimum vertical
vent run. If your installation has more than the minimum
required vertical vent length, adjustment of the air shutter
may be necessary to obtain optimal ame appearance.
This should be adjusted by a quali ed installer at the