Hearth and Home Technologies SL-750TRSFHHIPI Indoor Fireplace User Manual


 
27
Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08
Figure 7.6
Top Vent - Horizontal Termination - (continued)
Three Elbows
V
1
Minimum H
1
Maximum H
1
+ H
2
Maximum V
2
V
1
+ V
2
Minimum
Elbow only 1 ft. 305 mm 2 ft. 610 mm * *
1/2 ft.** 152 mm 2 ft. 610 mm 4 ft. 1.2 m * *
1-1/2 ft.** 457 mm 3 ft. 914 mm 6 ft. 1.8 m * *
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
H
2
H
1
V
2
V
1
Fire Risk.
When using SLP-HRC-SS and SLP-HRC-ZC-
SS termination caps on top vented replaces,
a one foot minimum vertical vent section is
required before installing rst elbow.
• When using DVP-TB1 termination cap on top vented
replaces, a three foot minimum vertical vent section is
required before installing rst elbow.
WARNING **