H
1
H
2
V
1
Figure 7.12
Figure 7.13
Two 90º Elbows
Rear Vent - Horizontal Termination
No Elbow
H
1
= 24 in. (610 mm) Maximum
H
1
Maximum V
1
Minimum H
2
H
1
+ H
2
Maximum
1-1/2 ft. 457 mm
Back to Back
Elbows
1 ft. 305 mm 2-1/2 ft. 762 mm
3-1/2 ft. 1.1 m 1 ft. 305 mm 3 ft. 914 mm 6-1/2 ft. 2.0 m
5-1/2 ft. 1.7 m 2 ft. 610 mm 5 ft. 1.5 m 10-1/2 ft. 3.2 m
7-1/2 ft. 2.3 m 3 ft. 914 mm 6-1/2 ft. 2.1 m 14 ft. 4.3 m
H
1
Maximum = 7-1/2 ft. (2.3 m)
H
1
+ H
2
Maximum = 14 ft. (4.3 m)
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m)
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
H
1
90-DEGREE ELBOWS
Use two 90º elbows for corner installations.
The use of two 90º elbows in a corner installation
will affect space requirements.
Two 90º Elbows
Note: Use DVP Series
components only.