Hearth and Home Technologies QV36D Indoor Fireplace User Manual


 
30
Installing the Trim
Combustible materials may be brought up to the specified
clearances on the side and top front edges of the fireplace,
but MUST NEVER overlap onto the front face. The joints
between the finished wall and the fireplace top and sides
can only be sealed with a 300° F. (149° C) minimum sealant.
WARNING: WHEN FINISHING THE FIREPLACE,
NEVER OBSTRUCT OR MODIFY THE AIR INLET/
OUTLET GRILLES IN ANY MANNER.
Install optional marble and brass trim surround kits as
desired. Marble, brass, brick, tile, or other non-combustible
materials can be used to cover up the gap between the
sheet rock and the fireplace.
Do not obstruct or modify the air inlet/outlet grilles. When
overlapping on both sides, leave enough space so that the
bottom grille can be lowered and the trim door removed.
!
Step 10. Installing Trim, Logs,
and Ember Material
Placing the Ember Material
Ember material is shipped with this gas fireplace. The bag
labeled Glowing Ember (050-721) is standard glowing ember
material.
To place the ember material:
Pull the four glass latches out of the groove on the glass
frame. Remove glass door from the unit (see Figure 39).
Place dime size pieces of ember material about 1/2 inch
apart near port holes in burner top. Do NOT press em-
bers into burner ports. Cover the top of the burner with a
single layer of ember material.
Save the remaining ember materials for use during fire-
place servicing. The bag of embers provided is sufficient
for 3 to 5 applications.
Replace the glass door and a front trim door on the unit.
Pull out and latch the glass clips into the groove on the
glass frame.
Aladdin Hearth Products fireplaces manufactured with tem-
pered glass may be installed in hazardous locations such
as bathtub enclosures as defined by the CPSC. The tem-
pered glass has been tested and certified to the require-
ments of ANSI Z97.1-1984 and CPSC 16 CFR 1202. (Safety
Glazing Certification Council SGCC # 1595 and 1597. Ar-
chitectural Testing, Inc. Reports 02-31919.01 and 02-
31917.01.)
This statement is in compliance with SPCS 16 CFR Sec-
tion 1201.5 “Certification and labeling requirements” which
refers to 15 USC 2063 stating “…Such certificate shall ac-
company the product or shall otherwise be furnished to any
distributor or retailer to whom the product is delivered.”
Some local building codes require the use of tempered glass
with permanent marking in such locations. Glass meeting
this requirement is available from the factory. Please con-
tact your dealer or distributor to order.
Figure 40. Placement of the Ember Material
Figure 39. Glass Assembly
Glass Specification: 24 1/2 x 35 1/2 TEMPERED
Positioning the Logs
The logs have been packaged separately, refer to the
instructions that accompany the logs. Save the log
instructions with this manual.
If sooting occurs, the logs might need to be repositioned
slightly to avoid excessive flame impingement.
___________________________________________
Shutter Settings
NG LP
Burner 3/16” Full Open (SET)
LATCHES
(BOTH BOTTOM
AND TOP)
GLASS
ASSEMBLY