Hearth and Home Technologies QV36D Indoor Fireplace User Manual


 
15
Figure 12.
Venting with One 90° Elbow
NOTE: If a 90
o
elbow is first attached to the unit,
the maximum horizontal run is 3-feet (914mm).
VENTING WITH ONE (1) 90° ELBOW
V (FT.) H (FT.)
1' MIN. (305mm) 5' MAX. (1.52m)
2' MIN. (610mm) 10' MAX. (3.1m)
3' MIN. (914mm) 15' MAX. (4.65m)
4' MIN. (1.22m) 20' MAX. (6.2m)
V+H= 40’ MAX. (12.4MM) H = 20' MAX. (6.2m)
VENTING WITH ONE (1) 90° ELBOW
V (FT.) H (FT.)
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6' MAX. (1.86m)
4' MIN. (1.22m) 8' MAX. (2.4m)
V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m)
NOTE: On vertical venting configurations where
the vertical component is over 10 feet, you may
want to install the vertical baffle included in the
manual bag assembly to improve flame
appearance.
Figure 11. Venting with One 90° Elbow
NOTE: For corner installations: A 6-inch (152mm)
section of straight pipe may need to be attached
to the fireplace before a 90
o
elbow, to allow the
vent pipe to clear the top standoffs.
H
V