Installation of Fireplace
CAUTION! Risk of Cuts/Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
A. Things to Consider
Location of chimney air kit
Location(s) of outside air kit
Electrical connections and/or wall switch
Gas line piping
Figure 7.1 Unpacking Back Refractory
Figure 7.2 Bending Refractory Shipping Tabs
Back Down
Remove back refractory from outside of replace by
bending tabs up and lifting refractory out of brackets.
See Figure 7.1.
Bend tabs back down out of the way. See Figure 7.2. Do
not remove screws or brackets from replace. If brackets
are removed, ll holes in outer shell with screws.
Repeat this process to remove side refractories.
D. Unpack the Fireplace (EXCLAIM-42 only)
C. Secure the Fireplace (EXCLAIM-36 only)
WARNING! Risk of Fire! Prevent contact with sagging,
loose insulation.
DO NOT install against vapor barriers or exposed
insulation.
Secure insulation and vapor barriers.
Provide minimum air space clearances at the sides
and back of the fireplace assembly as outlined in
Section 6.
• Place the replace on a continuous at surface.
Follow framing instructions in Section 6.
• Slide replace into position (brackets can be used to
anchor replace in position).
Skip to Section 7.G. for further EXCLAIM-36
instructions.
B. Unpack the Fireplace (EXCLAIM-36 only)
EXCLAIM-36 is shipped with refractory in place.
• Remove packaging.
Remove shipping brackets as shown in Figure 7.8.
Replace the screws removed from the replace.
Remove EXCLAIM-36 from pallet and set in place.
Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 11/08