Hearth and Home Technologies EXCLAIM-36 Indoor Fireplace User Manual


 
18
6
6
Framing & Clearances
F
D
E
A
5/8 in. (16 mm)
all configurations
In an exterior
chase or projecting
into a garage
Across a
corner
As a room
divider
Along a wall
G
B A
G
G
B
A
48 in.
(1219 mm)
min.
H
A
H
Note:
Note:
Exclaim-36 - 1 in. (25 mm)
Exclaim-42 - 1 1/2 in. (38
mm) minimum distance
from sides & back of
fireplace to combustible
materials.
BOTH - 1/2 in. (13 mm)
minimum at nailing flanges.
In addition to these
framing dimensions, also
reference the following
sections:
• Clearances (Section
6.B.)
• Mantel Projections
(Section 11.E.)
• Fireplace Dimensions
(Section 13.A.)
C
H
B
Figure 6.1 Fireplace Locations (Framing dimensions shown)
A. Select Fireplace Location
Model A B C D E F G H
EXCLAIM-36
inches 45 1/2 53 1/2 85 42 1/2 19 3/8 60 1/8 28
24 in. (610 mm)
Minimum from FP opening to
any perpendicular wall.
mm 1156 1359 2159 1080 492 1527 711
EXCLAIM-42
inches 52 59 1/2 92 3/4 46 3/8 21 1/2 65 5/8 28 1/2
mm 1308 1511 2356 1178 546 1667 724
Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 11/08