Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08 55
F. Install the Flame Solenoid
Gas Control
Valve
Variable
Regulator
Flame Control
Solenoid
Washer
Variable
Regulator
Variable
Regulator
Washer
Plunger
Jam Nut
Nut
Screw
Knob
Solenoid
Figure 12.3 Install the Flame Solenoid
• Remove the screw and knob from the variable regulator
and discard.
• Remove the nut from the regulator and discard.
• Remove the bag containing a washer and blue and red
plungers from the side of the fl ame control solenoid.
• Place washer on fl ame control solenoid.
• Insert the correct plunger (blue - natural gas, red -
propane) into the fl ame control solenoid.
• Thread the fl ame control solenoid with correct plunger
into the thread hole in the variable regulator. Turn into
valve approximately two full turns. Do not tighten or
damage may occur.
• Connect orange wires from control box to the fl ame
control solenoid.
G. Hook up the Temperature Sensor Switch
for Fan
• Find the two yellow wires from the WSK-MLT control box
and disconnect them.
• Connect one yellow wire to one jumper wire hanging
from the thermodisc.
• Connect the other yellow wire to remaining jumper wire
hanging from thermodisc.
• See Figure 12.2 for wiring diagram.