Hearth and Home Technologies CNXT4236ILT Indoor Fireplace User Manual


 
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08 43
B. Assemble Vent Sections (SLP Only)
To attach the rst vent component to the starting collars
of the appliance
Attach an SLP-DVP24 adapter to the starting collar of
the appliance.
Lock the vent components into place by sliding the pipe
section onto the collar.
Align the seam of the pipe and seam of collar to allow
engagement. Rotate the vent component to lock into
place. Use this procedure for all vent components. See
Figure 10.5.
Slide the gasket over the rst vent section and place
it flush to the appliance. This will prevent cold air
in ltration. High temperature caulk may be used to hold
the part in place.
Continue adding vent components, locking each
succeeding component into place.
Ensure that each succeeding vent component is securely
tted and locked into the preceding component.
1 - Align Seams
2 - Rotate
Figure 10.5 Adding Venting Components
WARNING! Risk of Fire or Explosion! DO NOT break
silicone seals on slip sections. Use care when removing
termination cap from slip pipe. If slip section seals are bro-
ken during removal of the termination cap, vent may leak.
Commercial, Multi-family (Multi-level exceeding
two stories), or High-Rise Applications
For Installation into a commercial, multi-family (multi-level
exceeding two stories) or high-rise applications: All outer
pipe joints must be sealed with high temperature silicone,
including the slip section that connects directly to the
horizontal termination cap.
Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections. See Figure 10.1
Only outer pipes need to be sealed. All unit collar, pipe,
slip section, elbow and cap outer ues shall be sealed
in this manner, unless otherwise stated.