Installing the Trim
Combustible materials may be brought up to the
specified clearances on the side and the top front edges
of the fireplace, but MUST NEVER overlap onto the
front face. The joints between the finished wall and the
fireplace top and sides can only be sealed with a 300
°
F.
(149
°
C) minimum sealant.
Install optional marble and brass trim surround kits as
desired. Marble, brass, brick, tile, or other non-
combustible materials can be used to cover up the gap
between the sheet rock and the fireplace. They can
overlap front face up to arch door front.
When overlapping on both sides, leave enough space
so the decorative door is accessible.
NON-COMBUSTIBLE FINISHING MATERIALS
MUST NEVER COVER/OVERLAP ARCHED
DECORATION DOOR.
Step 10
Glass Door
Removal,
Installing Trim,
Handle, Logs
and Ember
Material
CAUTION
Figure 28. Glass Door Removal
TOP TWO
SCREWS
BOTTOM
RETENTION
CLIPS
GLASS
ASSEMBLY
Remove the glass assembly. Using a phillips screw
driver, loosen the top two screws. Unfasten the bottom
retention clips and pull glass assembly out from the
bottom. See Figure 28.
Removing Glass Door