Hearth and Home Technologies BE-36-CIPI Indoor Fireplace User Manual


 
Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05
33
Figure 35. Fan Wiring Diagram
FAN
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
JUNCTION BOX
Figure 34. Intermittent Pilot Ignition (IPI) Wiring Diagram
NOTE 1: Ignition module, valve, pilot and
wall switch operate on 3 volts. 120 VAC
is required at junction box unless
equipped with battery back-up.
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 C RATED WIRE.
O
JUNCTION BOX
VARIABLE SPEED CONTROL
TEMPERATURE
SENSOR SWITCH
WHT
GRN
BLK
BLK
110-120 VAC
BLOWER
BLOWER RECEPTACLE
BLK
BLK
BLK
BLK
WHT
GROUND
WHT
BLK
BLK
BLK
JUMPER WIRE
(TO BROWN)
GREEN
ORANGE
V
ALVE
PLUG-IN
TRANSFORMER
3 VAC
B
L
A
C
K
R
E
D
BATTERY
PACK
ORG
WHT
GROUND TO
FIREPLACE
CHASSIS
I
S
IGNITION
MODULE 3 VAC
INTERMITTENT
PILOT IGNITOR
BLOWER
SENSOR
SWITCH
“FAN”
RECEPTACLE
SPEED
CONTROL