SPECIFICATIONS:
LISTED: DIRECT VENT GAS HEATER
Listed: DV Gas Heater
Model: Champlain DV Room Heater
Testing Agency: Intertek Testing Services NA Inc. (ITS)
Tested to: ANSI Z21.88-1998, CSA 2.33-M98, CAN/CGA2.17
Figure 1: Champlain Dimensions
NG LP
Input rating (Btu/hr) 0-2000ft 37,000
37,000
Maximum output (Btu/hr) 0-2000ft 26,200
26,800
Minimum input rating (Btu/hr) 20,300
22,600
Orifice size DMS 0-2000ft 31 49
Man. pressure- HI setting (in.w.c./kPa) 3.5/0.84
10.0/2.48
Man. pressure- LO setting (in.w.c./kPa) 1.2/0.30
3.3/0.80
Inlet pressure-HI (in.w.c./kPa.) 7.0/1.74
13.0/3.22
Inlet pressure-Lo (in.w.c./kPa) 5.0/1.24
11.0/2.75