Figure 16: Log Set Assembly.
REMOVAL OF THE LOG SET
To remove the log set, follow the
Installation of Log Set instructions in the
reverse order.
LIGHTING THE UNIT FOR
THE FIRST TIME
DO NOT LIGHT THE UNIT WITHOUT
THE GLASS AND CAST FAÇADE IN
PLACE!
WARNING: If you do not follow these
instructions exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
CAUTION: Lighting the Champlain for
the first time and adjustments to the unit
should be performed by qualified service
personnel.
SMOKE AND FUMES WARNING
When lit for the first time, the Champlain
will emit some smoke and fumes. This is
normal “off-gassing” of the paints and oils
used in the manufacturing and assembly of
the unit. Open windows to vent the room if
necessary. The off gassing and fumes will
subside after the first 10 to 20 minutes of
operation.
ODORS AND IMPURITIES
A heater of this type may produce odors
during heater operation due to impurities
that may exist in the immediate area.
Sources of impurities can be cleaning
solvents, paint solvents, cigarettes, smoke,
pet hair, dust, adhesives, new carpet, and/or
textiles. Such odors will dissipate. However,
opening a window or otherwise providing
additional ventilation to the area can
alleviate the condition. If any odor persists,
contact your dealer or an authorized service
technician.
PILOT LIGHT WARNING
The Champlain has a piezoelectric spark
igniter (the red push button located next to
the gas control valve behind the valve access
door, which ignites the pilot light by means
of a spark at the pilot light assembly. Do
not attempt to light the unit with a match or
by any means than the piezoelectric spark.
PREPARE FOR LIGHTING
Prepare for the lighting procedure by
adjusting the thermostat (if equipped) to its
lowest setting or OFF position. If the gas
control knob is not in the OFF position, turn
the knob fully clockwise to OFF. Locate the
variable output control knob and turn it fully
clockwise to the highest setting.
Prior to lighting the unit for the first time,
wait 5 minutes to allow any residual gas
within the unit to dissipate. Smell all around
the appliance area for gas. Be sure to smell
next to the floor because some gases are
heavier than air and will settle on the floor.
If you do not smell gas after this five-minute
period, proceed with the lighting procedure.
If you do smell gas, DO NOT proceed with
the lighting procedure. Instead, immediately
refer to the What To Do If You Smell Gas
Warning, on the cover of this manual.