LISTINGS AND SPECIFICATIONS
QUADRA-FIRE 800 NOVA pellet stoves are safety tested and listed with Warnock Hersey International to ASTME 1509 and ULCS627.
Also suitable for mobile home installation (see page 11 for details).
HEAT INPUT*: 28,000 to 37,500 BTU per hour
PARTICULATE EMISSIONS PER HOUR: 0.9 grams per hour
DIMENSIONS: WIDTH-261/2" (673mm), DEPTH-24” (609mm), HEIGHT-291/2" (749mm)
*BTU INPUT WILL VARY, DEPENDING ON THE BRAND OF FUEL YOU USE IN YOUR STOVE.
CONSULT YOUR QUADRA-FIRE DEALER FOR BEST RESULTS.
INSTALLATION
CLEARANCES TO COMBUSTIBLES
Minimum Clearances To Combustible Material (USA in inches, Canada in mm).
RESIDENTIAL/MOBILE HOME RESIDENTIAL/MOBILE HOME RESIDENTIAL/MOBILE HOME RESIDENTIAL/MOBILE
HOME
A = 8” (150mm) A = 8” (150mm) F = 2” (50mm) C = 3” (75mm) D = 8” (200mm)
B = 2” (50mm) C = 3” (75mm) Horizontal and Vertical (from side of the stove face)
Horizontal Installation Vertical Installation Comer Installation E = 2” (50mm)
with 6” (152mm) Top Vent Kit
CLEARANCES TO COMBUSTIBLES (USA IN INCHES, CANADA IN MM)
Top Vent Top Vent
Rear Kit With Kit With
Vent 3” Pipe 6” Pipe
Back: 2” (50mm) 8” (200mm) 9” (225mm)
Side: 2” (50mm) 2” (50mm) 2” (50mm)
Corner: 2” (50mm) 2” (50mm) 2” (50mm)
From side of stove face: 8” (200mm) 8” (200mm) 8” (200mm)
CHIMNEY AND EXHAUST CONNECTION
1. CHIMNEY & CONNECTOR: Use 3” (76mm) or 4” (102mm) diameter type “L” or ”PL” venting system.
2. MOBILE HOME: Approved for all listed pellet vent. If using the 3" (76mm) or 6" (152mm) vertical top vent kit, you must use either
listed double wall flue connector to Class A pipe, or all Class A pipe. Mobile home venting system must be equipped with a spark
arrestor and rain cap.
3. RESIDENTIAL: The 3" (76mm) and 6" (1 52mm) vertical top vent kits are tested to use 24 gauge single wall flue connector or listed
double wall flue connector to Class A listed metal chimneys or masonry chimneys meeting ICBO standards for solid fuel appliances.
4. The stove is approved for all 3" (76 mm) or 4" (102 mm) diameter listed pellet vent. It can be either vertically or horizontally vented.
NOTE: All pipe must be sealed using welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500
°°
°°
°F
[260°[260°
[260°[260°
[260° C] minimum rated only).