Hearth and Home Technologies 7100FP-NL-B Indoor Fireplace User Manual


 
September 1, 2008
433-1390G
Page 17
7100FP EPA Woodburning Fireplace
R
Figure 17.1 Outside Convection Air Placement
Outlet blocked by
snow, leaves, etc.
NO
Garage or
combustible
liquids storage
NO
Attic space
NO
Outlet placed
higher than 3 ft
below the
termination cap
NO
Use only duct materials
specified by manufacturer
Both the Outside Air and Auxiliary Air kits are installed
on the right hand side of the fireplace.
Left = Room Air Right =Auxiliary Air
B. Auxiliary Convection Air System
Figure 17.2 Auxiliary Convection Air Lever
Auxiliary convection air allows you to use outside air to flow
over the blowers, where it is heated and then distributed
into the room producing positive pressure inside the home.
Alternatively, you can also run a 6 in. (152 mm) duct to another
location in your home and use as a cold air return within the
home.
The auxiliary convection lever allows you to change the
fireplace from a zone heater into a whole house heater.
LEFT: Slide to the left and use the fireplace as a zone heater.
This option pulls room air into the bottom grille of the fireplace,
heats the air and re-circulates it to the room(s).
RIGHT:
Slide to the right and use the fireplace as a whole
house heater for room convection air.
The auxiliary convection lever
is located underneath the front
lower panel. See Figure 17.2.