Hearth and Home Technologies 7100FP-BK-B Indoor Fireplace User Manual


 
September 1, 2008
433-1390G
Page 11
7100FP EPA Woodburning Fireplace
R
B. Clearances
Figure 11.1 Clearances to Combustible Materials
Fire Risk
Comply with all minimum clearances to combustibles as specified.
Framing or finishing material used on the front of, or in front of, the
appliance closer than the minimums listed, must be constructed entirely
of non-combustible materials (i.e., steel studs, concrete board, etc.).
Failure to comply may cause fire.
WARNING
2 in. (51 mm) min.
Attic
Insulation
Shield
Ceiling Firestop
(ceiling)
(roof)
(attic)
(ceiling)
Ceiling Firestop
Offset/Return with
hanger straps
Storm Collar
Roof Flashing
2 in. (51 mm) min.
2 in. min.
(51 mm)
Must have 2 in. (51 mm)
minimum clearance
to header
2 in. (51 mm) min.
2 in. (51 mm) min.
2 in. (51 mm) min.
2 in. (51 mm) min.
1 in. (25mm) to side of appliance
(except at nailing flanges where it is 1/2 in. [13 mm])
1/2 in. (13 mm) to back
of appliance
0 in.
to floor
0 in. to level
of standoffs