Hearth and Home Technologies 6000GBV-LP Indoor Fireplace User Manual


 
Heat & Glo • 6000GBV, 6000GBV-IPI • 2104-900 Rev. H • 11/08 19
5
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traf c and away from furniture and draperies.
NOTICE: Illustrations re ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
A
B
B
B
C
D
E
TOP VENT
TOP VENT
ALCOVE
INSTALLATION
TOP VENT
A
F
ABC D E F
Inches 51 42 72
See Mantel
Projections
22 1/2
Millimeters 1295 1067 1829 559 13