Harman Stove Company Super Magnum Coal Stoker Stove Stove User Manual


 
15
Do Not Burn Wet Coal!
Super-Magnum Coal Stoker Stove
3-90-02702R4_08/12
6
Mobile Home
A. Mobile Home Installation
Mobile home approval - U.S. only.
1. An outside air inlet must be provided for
combustion air, and must remain clear of leaves,
debris, ice, and/or snow. The outside air path must
be unrestricted while the appliance is in operation.
2. The combustion air intake system must be of
metal construction. It must permit zero-clearance
to combustible materials, and contain a rodent
screen.
3. The appliance must be secured to the mobile
home structure by bolting it to the oor. There are
brackets included, you'll need to secure with the
proper length lag bolts.
4. The appliance must be grounded to the metal
framing of the mobile home
5. All clearances to combustibles and oor protection
requirements must be followed.
6. Follow the vent manufacturer's instructions when
installing in a mobile home.
7. Installation shall be in accordance with the
Manufactured Home and Safety Standard (HUD)
CFR 3280, Part 24
8. The appliance must never be installed in a room
designated for sleeping.
This diagram shows the bracket that was used to
bolt the stove to the pallet. Use at least two of these
brackets for securing the appliance through the oor in
a mobile home installation. The bracket will slip over
the top of the leveling adjuster. The installer will need
to determine and obtain the properly sized lag bolts.
Installation must comply with Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
WARNING
Never install in a room intended for sleeping.
WARNING
Maintain structural integrity of mobile home:
Floor, wall, ceiling and/or roof.
Do NOT cut through:
Floor joist, wall studs, or ceiling trusses.
Any supporting material that would affect the
structural integrity.
CAUTION
Never draw outside combustion air from:
Wall, oor or ceiling cavity.
Enclosed space such as an attic or garage
CAUTION