Harman Stove Company PP38+ Stove User Manual


 
P38+ Pellet Stove
6
CAUTION
Place the stove on a noncombustible floor protector that
extends 6 inches to the front, 6 inches to the sides and 1 inch
to the rear of the stove. The minimum floor protector material
is 24 gauge sheet metal.
Place the stove away from combustible walls at least as
far as shown in figures 3,4 and 5. Please note the difference in
side wall clearance with and without side shields.
Note that the clearances shown are minimum for safety
but do not leave much room for access when cleaning or
servicing. Please take this into account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommened to protect the
circuit board).
Prior to installing flue pipe, connect a draft meter to the
stove as shown in fig. 6 . (The draft meter must have a mini-
mum range of 0-.5). Set control board to "1" on the feed rate
dial. Record draft reading here _______ (should read at least
.15" cold. Allow combustion blower to operate for approxi-
mately 1 minute before recording or adjusting low draft.). See
page 19 for low draft adjustment procedures.
After connecting the flue system, follow the above pro-
cedure. However, prior to taking the draft reading be sure all
doors and windows in the home are closed. Record the draft
reading_______. If this reading is more than .05" lower than
the unconnected reading, check for possible restrictions or
the need for outside air (see page 7).
Mobile Home Installation
When installing this unit in a mobile home several require-
ments must be followed:
1. The unit must be bolted to the floor. This can be done
with 1/4" lag screws through the 2 holes in the base plate.
2. The unit must also be connected for the outside air. See
page 8.
3. Floor protection and clearances must be followed as
shown.
4. Unit must be grounded to the metal frame of the mobile
home.
CAUTION: This appliance must be vented to the outside.
The stove is hot while in operation.
Keep children, clothing and
furniture away. Contact may cause
skin burns.
6"
Fig. 4
10"
2"
1"
6"
With Side Shields
FLOOR PROTECTOR
6"
Fig. 5
16"
Without Side Shields
FLOOR PROTECTOR
2"
2"
FLOOR PROTECTOR
Fig. 3
Fig. 6
Installation
Mobile home installation should be done in accordance
with the Manufactured Home and Safety Standard (HUD),
CFR 3280, Part 24.