Harman Stove Company P61A-2 Stove User Manual


 
8 P61A!!Pellet!Stove
#2!Preferred!method
This!method!also!provides!excellent!venting!for
normal!operation!but !requires!the!stove!to!be!installed
farther!from!the!wall.!The !vertical!portion!of!the!vent
should!be!three!to!five!feet!high!and!at!least!three!inches
from!a!combustible!wall.!This!vertical!section!will!pro-
vide!natural!draft!in!the!event!of!a!power!failure.
If!the!stove!is!installed!below!grade!be!sure!the
vent!termination!should!be !at!least!1!foot!above!grade.
CAUTION
Keep!combustible!materials!(such
as! grass,!leaves,! etc.)! at!least! 3! feet
away!from!the!flue!outlet!on!the!outside
of!the!building.
#1!Preferred!method
This!method!provides!excellent!venting!for!normal
operation!and!allows!the!stove!to !be!installed!closest!to
the!wall.!Two!inches!from!the!wall!is!safe;!however ,!four
inches!allows!better!access!to!remove!the!rear!panel.
The!vertical!portion !of!the!vent !should!be!three!to!five
feet!high.!This!vertical!section!will!provide!natural!draft
in!the!event!of!a!power!failure.
Fig.!8
Fig.!9
3!ft.
to!combustibles
3!ft.
to!combustibles
Venting