14 P61A!!Pellet!Stove
The!P61A!Pellet!Stove!is!capable!of!manual!operation.!This!also!allows!the!operator!to
manually!control!operation!during !an!emergency!(i.e.!ignitor!failure,!when!using!a!502H!battery
backup,!or!when!using!certain!generators.)
The!unit!can!be!switched!between!"AUTO"!and!"MANUAL"!at!any !time!during!operation.
Ignitor!Switch!to!"MANUAL"
Room!Temperature! Mode
The!fire!will!have!to!be!lit!with!starting!gel!and!a!match,
or!started!automatically,!see!"Automatic!Operation".!Turn
to!"Manual"!position!when!the!fire!is!established.
The!difference!between!"AUTO"!Room!Temperature
Mode!and!"Manual" !Room!Temperature!Mode !is!that!the
fire!will!not!go!out!as!the!room !temperature!goes !above!the
control!board!setting.!The!unit!can!only!go !to!low !burn!and
will!remain!there!until!it!runs!out!of!fuel!or!until!more!heat!is
needed!and!the !feed!rate!increases. !Feed!rate!adjustments
and!dial!settings!are!the!same!as!"AUTO"!settings.
Ignitor!Switch!to!"MANUAL"
Stove! Temperature! Mode
The!advantage!of!this!mode!is!to!allow!the!operator!to
have!a!large!viewing!fire!without!blowing!extra!heat!into!the
room.
During!operation,!with!the!temperature!dial !set!at!#5
or!less,!the!distribution!fan!will!not!operate.!A!#5!on!the
temperature!dial!and!a!#5!on !the!feed!adjuster!is!approxi-
mately!80%!output.!It!is!not!necessary!to!operate!the !distri-
bution!blower!below!this!point.!Therefore,!there!can!be!a
higher!feed!rate!(!a!larger!viewing!fire)!without!an!excess!of
hot!air!blowing!into!the!room.
An!example!of!when!to!use!the!Manual!Stove!Tem-
perature!Mode!is!if!you!want!to!watch!a!large!fire!and!the
room!is!aleady!!up!to!temperature. !The!Stove!Temperature
Mode!allows!you!to!have!a!larger!fire!and!a!lower!sound
level,!without!the!distribution!blower.
NOTE:!During!the!use!of!this!mode,!if!you!keep
increasing!the!temperature !dial!setting!to!increase!the
fire!size,!the!distribution!blower!will!automatically!come
on!when!the !ESP !Temperature!reaches!350
o
!F,!or!81%
output.
NOTE:!When!starting!the!unit!in!the!"AUTO"
mode!and!switching!to!"MANUAL",!the!fire!must!be
large!enough!to!start!!the!distribution!blower.!The!start-
ing!of!the!blower!is!a!signal!that!the!start!cycle!is!com-
pleted!and!the!fire!will !not!go!out.
P61A-2!!MANUAL!!IGNITION/OPERATION
This!setting!will!produce!a!large!viewing!fire!without
a!distribution!blower!operating.
Manual!Stove!Temperature!Mode
Room!Temperature!Mode:!This!setting!will!produce!a!room
temperature!of!70!degrees! with!the!distribution!blower! at
medium!speed.
O
O
O
O
o
o