16 P61A!!Pellet!Stove
O
O
P61A-2!!AUTOMATIC!IGNITION!!ESP!!CONTROL
Feed!adjuster
Sets!the!maximum!feed
rate
Test
Runs!all!motors!at!full
speed!for!one!minute
to! check! operation.
After!two!minutes!the
stove! will! go! to
minimum!burn!and!the
blowers!will!alternate
from!high!to!low!every
minute!to!remind!you
that! you!are! still! in
"Test!Mode".
Ignitor!switch
Set!to!appropriate
Start-Up!mode.
Distribution!Blower!speed
adjustment!range.
L!=!low
H!=!high
Variable!speed!anywhere
between! L! and! H;
although! as! the! stove
temp.!goes!up!,!so!does!the
L!and!H!scale.
Temp!dial
Allows!you!to!adjust!the!room!temperature!in! Room!Temp
Mode!using!the!outer!scale!marked!in!degrees!Fahrenheit.
It!also!allows! you!to!adjust!the!stove!temperature!while!in
Stove!Temp!Mode!using!the!inner!scale!marked!from!1!to!7.
Mode!Selector
Allows!you!to!choose!between
Room!Temp!Mode,!Stove!Temp
Mode,!or !OFF.!Also !allows!you
to!vary!the!distribution!blower
speed!by!turning!the!knob!to
the!high!or!low!side!of!each
mode.
Power!Light
Indicates!power!to!the
control.
Indicates!power!to!the
feed!motor.
Indicates!ignitor!is!on.
!Indicates!power!to
combustion!blower
Status!Light
Will!be!lit!in!either!stove!or
room!temp!mode!when
pointer!is!not!within!off
position!band!except!after
normal!shut!down.!Blinks
to!indicate!errors!listed
below.
Indicates!power!to
distribution!blower.
Status!light!error!messages:
1!Blink:!Indicates!control!board!self!diagnostic!failure.
This!requires!a!manual!reset*.
2!Blinks:!!Indicates!that!the!jumper!(J2)!on!the!rear!of
the!control!board!is!not!connected.!Without!this!jumper
the!unit!will!only!burn!at!minimum!rate.
3!Blinks:!Indicates!ESP!(Exhaust!Sensing !Probe)!fail-
ure.!This!requires!a!manual!reset*.
4!Blinks:!Can!occur!only!in!Room!Temp!Mode!and
indicates!Room!Sensing!Probe!failed!or!not!installed.!If
a!Room!Sensing!Probe!is !then!installed,!the!status!light
will!automatically!reset.
5!Blinks!(In!Igniter!Auto.!Mode!Only):!!Indicates
that!the!unit!has!failed!to!light!within!the!36!minute!start
cycle.!To!reset!-!Turn!Mode!Selector!to!"OFF",!then
turn!to!either!mode!again.)
6!Blinks!:!Indicates!that!the!control !has!calculated !poor
or!incomplete!combustion !occurring!for!more!than!50
minutes.
A!six!blink!status!may!be!set!if!the!stove!is!allowed!to
run!out!of!pellets.!To!reset,!turn!mode!selector!to!"OFF"
then!back!on!to!the!desired!mode.!If!the!unit!was!not
out!of!pellets,!see!Troubleshooting !section!for!more!de-
tails.
*!Manual!reset-!disconnect!power!cord!for!a!few!sec-
onds!and!reconnect.!If!error!still!occurs!call!your!Dealer .
NOTICE:!When!power !is!given!to!the!stove,!the !con-
trol!board!will!blink!a!few!times!to!indicate!current!ver-
sion!of!control!board.!This!should!not!be!confused!with
error!messages.
Dealer!Diagnostic!Port
For! dealer! maintenance
only.!Requires!special!DDM
monitor!supplied!to!Harman
Dealers!exclusively.