Harman Stove Company P43 Stove User Manual


 
2
P43 Pellet Stove
Harman PP38+/P43 Pellet Stove
Label measures: 4-3/8" high X 9-3/4"wide
MINIMUM CLEARANCES
TO COMBUSTIBLES:
SIDEWALL TO STOVE 16" 10"
BACKWALL TO STOVE 2" 2"
CEILING TO STOVE TOP 18" 18"
STOVE CORNER TO DIAGONAL WALL 9" 9"
PREVENT HOUSE FIRES, OPERATE WITH VIEWING & ASH DOOR CLOSED.
UNIT MUST BE PLACED ON A NON-COMBUSTIBLE FLOOR PROTECTOR EXTENDING
6" TO THE FRONT, 6" TO SIDES AND 1" TO REAR. MEASURE FRONT FROM GLASS.
EXHAUST TYPE: LISTED TYPE L OR PL VENT INSTALLED TO VENT MANUFACTURER'S
INSTRUCTIONS AND LOCAL BUILDING CODES.
ELECTRICAL RATING: 6 AMPS, 120 VOLTS, 60 HERTZ
FUEL: PELLETIZED OR BIOMASS
INSTALL AND USE ONLY IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION
AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS
ABOUT RESTRICTIONS & INSTALLATION INSPECTION IN YOUR AREA.
EPA EXEMPT PER 40 CFR 60.534, METHOD 28A.
APPROVED FOR USE IN MOBILE HOMES.
INPUT RATING: .75 TO 5.5 LBS PER HOUR.
DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.
NE PAS CONNECTER CET APPAREIL À UNE CHEMINÉE SERVANT UN AUTRE
APPAREIL.
LISTED PELLET FUEL BURNING ROOM HEATER APPAREIL DE CHAUFFAGE CATALOGUÉ DE
MODÈLE POUR BRÛLER DES BOULETTES COMBUSTIBLES.
MODEL / MODÈLE: "PP 38+" / "P43"
INSTALL WITH MINIMUM CLEARANCES TO WALLS AS
SHOWN / INSTALLER AVEC LES DISTANCES MINIMUM
DE SECURITÉ COMME INDIQUÉ.
TESTED TO : UL 1482 ASTM E1509
OREGON 814-23-900
ULC-S627
WH-PN 025
TEST DATE: JUNE 1997
WITHOUT
SIDE SHIELDS
WITH
SIDE SHIELDS
ESPACES LIBRES MINIMUM
DES MATÉRIAUX COMBUSTIBLES:
DU MÛR DE CÔTÉ AU POÊLE 406 mm 254 mm
DU MÛR ARRIÈRE AU POÊLE 51 mm 51 mm
DU PLAFOND AU DESSUS DU POÊLE 457 mm 457 mm
DU COIN DU POÊLE AU MÛR DIAGONAL 229 mm 229 mm
PRÉVENIR LES FEUX DE MAISONS. OPÉRER SEULEMENT AVEC LA PORTE
D'OUVERTURE ET LA PORTE DES CENTRES FERMÉES. L'APPAREIL DOIT ÊTRE
PLACÉ SUR UN PLANCHER PROTECTEUR INCOMBUSTIBLE, CELUI-CI S'ÉTENDANT
DE 152 mm EN AVANT, DE 152 mm DES CÔTÉS ET D 25 mm DE L'ARRIÈRE.
SORTE D'ÉCHAPPEMENT: VENTILATEUR DE TYPE L OU PL INSTALLÉ SELON
LES INSTRUCTIONS DU FABRICANT ET SELON LES CODES LOCAUX DE LA
CONSTRUCTION.
PUISSANCE ÉLECTRIQUE: 6 AMPS, 120 VOLTES, 60 HERTZ
COMBUSTIBLE: DE BOULETTES COMBUSTIBLES OU BIOMASSES.
INSTALLER ET UTILISER SELON LES INSTRUCTIONS D'INSTALLATION ET
D'OPÉRATION DE FABRICANT. CONTACTER LE BUREAU DE LA CONSTRUCTION OU
LE BUREAU DES POMPIERS AU SUJET DES RESTRICTIONS ET DES INSPECTIONS
D'INSTALLATION DANS VOTRE VOISINAGE.
EXEMPTION EPA PAR 40 CFR 60.534, DE MÉTHODE 28a
APPROUVÉ POUR L'USAGE DANS LES MAISONS MOBILES
PUISSANCE ESTIMÉE: .75 À 5.5 LBS PAR HEURE.
SANS LES
PROTECTEURS
DE CÔTÉ
AVEC LES
PROTECTEURS
DE CÔTÉ
WHI -
DO NOT REMOVE THIS LABEL.
NE PAS ENLEVER CETTE ÉTIQUETTE.
MADE IN USA
W/N 02531
DISTANCES AUX MURS
LATÉRAL ET ARRIÈREAVEC
PROTECTIONS MURALES
SIDEWALL-BACKWALL
INSTALLATION WITH
SIDE SHIELDS
2"/51mm
10"
254mm
DISTANCES AUX MURS
LATÉRAL ET ARRIÈRE SANS
PROTECTIONS MURALES
2"/ 51mm
SIDEWALL-BACKWALL
INSTALLATION WITHOUT
SIDE SHIELDS
16"
406mm
INSTALLATION EN ANGLE 229mm
AVEC OU SANS PROTECTIONS
MURALES
CORNER INSTALLATION 9" WITH
OR WITHOUT SIDE SHIELDS
9" / 229mm
9" / 229mm
P.N. 3-90-04300
BAR CODE LABEL
TAILLE MINIMALE
DE LA PROTECTION DE SOL.
6" /
152mm
1"/25mm
FLOOR PROTECTOR
MINIMUM SIZE
6" /
152mm
6" /
152mm
Manufactured By / Fabrique Par:
352 MOUNTAIN HOUSE ROAD
HALIFAX, PA 17032