INSTALLATION
Only For Qualified Installers
Installing Fireplace To use
Victorian Face
When installing the fireplace to use the Victo-
rian Face the unit must be positioned back 1/2 inch
farther than with an arch face. A special drywall
bracket must be used to allow the drywall to extend
down far enough so the face will cover the drywall.
1. Install drywall bracket on top of the stand-offs
with two screws.
2. Place the fireplace into the framed opening so
the two ends of the drywall bracket rest against
the framing. This will position the face of the
fireplace 1/2 inch back from the face of the
framing.
3. Nail or screw the drywall bracket fast to the
framing.
4. Install and finish drywall as desired. Drywall
shall not extend below the drywall bracket on
the top and not closer to the fireplace cabinet
than the vertical wood framing on the sides.
Drywall Bracket
Nails
Nails
Drywall Bracket
Drywall
Victorion Face