Harman Stove Company 929BV Stove User Manual


 
9
WARNING: THIS HEATER IS EQUIPPED WITH
A THREE-PRONGED GROUNDING PLUG THAT
SHOULD BE PLUGGED DIRECTLY INTO A PROP
-
ERLY GROUNDED RECEPTACLE. DO NOT CUT
OR REMOVE THE GROUNDING PRONG FROM
THE PLUG.
Terminal strip for
thermostat connec-
tion
Rear view of Clarity
CONNECTING THE CORDSET
The Clarity B-Vent Gas Heater must be installed in ac-
cordance with local codes or, in the absence of local codes,
with the most recent edition of the National Electrical Code
ANSI/NFPA 70, or the current Canadian Electrical Code
C22.1.
NOTE: The convection fan requires a 120 VAC supply
for operation, but the heater can be operated without the fan
as in the case of a power outage.
Plug the 3-prong grounded electrical cord plug into
the wall.
CONNECTING THE
OPTIONAL THERMOSTAT
If connecting the optional thermostat, it must be plugged
into the terminal strip located on the left side near the bot
-
tom of the stove.
Wh en in st al li ng a m il li vol t co nt ro l s ys
-
tem, use only a special low resistance thermostat.
Do not use a regular heating thermostat.
Be sure that all electrical connections are clean, free
from corrosion, and tight. Inspect connections periodically
to conrm that no corrosion has built up over time.
When properly installed and maintained, a millivolt
control system should give many years of trouble-free
service.
It is important to use wire of a gauge proper for the
length of the wire:
RECOMMENDED WIRE GAUGES
Maximum Wire
Length Gauge
100' 14
60' 16
40' 18
25' 20
15' 22