Harman Stove Company 828i Indoor Fireplace User Manual


 
22
10-23-97
Specifications
Tested to ANSI Z21.88-2002, CSA 2.33-M02, CAN/CGA 2.17-M91.
NATURAL GAS PROPANE
Input Rating (Btu/hr) (0-1370 m) 37,000 37,000
Min. Input Rating (Btu/hr) (0-1370 m) 25,000 27,500
Injector Sizes (DMS) (front/center/rear (0-1370 m) 47/56/44 57/71/55
Manifold Pressure (in w.c./kPa) 3.5/0.87 10.0/2.49
Minimum Manifold Pressure (in w.c./kPa) 1.7/0.42 5.9/1.47
Minimum Inlet Pressure (in w.c./kPa) 5.0/1.25 11.0/2.74
Maximum Output (Btu/hr) (0-1370 m) 27,600 28,400
AFUE (seasonal efficiency; minimum venting)
64.9
%
67.0
%
Steady State Efficiency (max. input, blower on High)
77.2
%
78.6
%
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to side wall or combustible trim ...................................... 10 in. (254 mm)
Unit to mantel and combustible trim, unprotected.................. 12 in. (305 mm)
Electrical Rating: 120 Volts, 60 Hz., 1.2 Amp
25.427
19.075
21.650
10.412
7.75
44 (std.)
40 (opt.)
32.5 (std)
30 (opt)
4" Vent