Hampton Direct U32 Indoor Fireplace User Manual


 
10 U32-5 FPI Direct Vent Gas Insert
LOG SET INSTALLATION
Log kit (Part # 425-930) contains the following pieces:
a) 27-31 Rear Log
b) 27-32 Middle Left Log
c) 27-33 Front Log
d) 27-34 Middle Right Log
e) 27-35 Left Log
f) 27-36 Right Log
g) 902-154 Embers Lava
h) 902-179 Vermiculite
i) 902-153 Rock Wool
j) 946-669 Platinum Embers (supplied with packaged manual)
27-34
27-33
27-31
27-36
1) Carefully remove the logs from the box and unwrap them. The logs
are fragile, handle with care - do not force into position.
3) Fit log 27-31 into the pins on the rear log tray.
4) Fit log 27-32 into the pins on the middle left hand side of the
burner.
27-32
27-32
27-35
Vermiculite and Embers
27-31
Read the instructions below carefully and refer to the images.
Dangerous operating conditions may occur if the logs are not
positioned in their correct locations. If the logs are broken
do not use the unit until they are replaced. Broken logs can
interfere with the pilot operation.
IMPORTANT
For LP units the Air Defl ector MUST be installed prior
to log installation. See "Conversion from NG to LP"
section in manual for installation instructions.
2) Spread vermiculite around the exposed fi rebox base. Then take some
embers and spread them over the vermiculite as shown.
INSTALLATION