Haier HSU-09HSA03/R2(DB) Air Conditioner User Manual


 
Haier air conditioner Edition: 20070116
- 61-
6.3 Air outlet temp.-ambient temperature curves
HSU-09HSA03/R2(DB)
Air outlet temp. - Ambient temp. table
Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB
18ć 20ć 25ć 32ć 35ć 40ć 43ć 46ć
18/12ć
9.30 9.69 9.81 10.10 12.10 12.66 11.52 10.67
18/14ć
9.47 9.74 10.10 10.64 12.16 12.85 11.77 11.19
20/15ć
10.29 10.64 10.91 11.65 13.46 13.97 12.82 12.39
22/16ć
10.74 11.20 11.68 12.31 14.19 15.00 13.51 12.80
25/18ć
11.63 12.14 12.52 12.93 14.85 15.50 14.44 14.10
27/19ć
12.41 12.80 13.42 13.89 15.99 16.37 15.23 14.60
30/22ć
12.69 13.04 13.75 14.29 16.08 16.72 15.31 14.75
32/23ć
12.69 13.15 14.00 14.46 16.32 16.71 15.44 15.12
32/24ć
12.76 13.15 13.97 14.54 16.42 16.81 15.64 15.11
$LURXWOHWWHPS$PELHQWWHPSFXUYHV












 ć


ć
  ć
  ć

 ć
  ć
  ć
  ć


ć
,QGRRUWHPS'%:%
Air outlet temp. (ć)
ć
ć
ć
ć
ć
ć
ć
ć