Haier HSU-09HSA03/R2(DB) Air Conditioner User Manual


 
Haier air conditioner Edition: 20070116
-27-
15s panel indicator extinguish, failure list express mode be canceled.
Previous alarm information sent to display panel to indicate operating status.
After 10s, cancel fault indicator (fault list indicator show for 10s only).
During showing the fault status, don’t receive other signal.
In normal mode, nothing is shown only buzzer sound.
ĒĒ Air deflector control
20.1 Vertical swing
20.1.1 During power on, the entire output parts act along close direction.
20.1.2 Set position, after power restart and initialize, direct to remote control position.
20.1.3 Louver position
Position1 position2 position3 position4 position5 position6
10º from level 25º from level 40º from level 55º from level 70º from level cool45ºHeat 60º
20.1.4 Dispose on swing of remote control.
20.1.4.1 The swing will move in the following direction when the unit is cool/ dry/ fan. Position 1 (Initial
position)---position 2---position 3----position 4-----position 5 -----position 6---. ……circulating
20.1.4.2 The swing will move in the following direction when the unit is making heat:
Position 5 (Initial position)----position 4 ----position 3 ---position 2--- position 6 ----position
5 ……circulating.
20.1.5 Dispose on swing indoor.
20.1.5.1 The unit will execute according to board indication when the unit is cool/heat/ dry.
When it runs under automatic mode, the host unit will enter heat-making mode based on indicated
position of the board. When it runs under automatic mode, host unit has no position (After receiving the
mode of position 5, the unit will dispose the data based on position 4).
20.1.5.2 When operation is off.
When operation is off or timing is on, all-close output parts will move into close direction.
When all-close output starts to operate, namely, it will move into open direction.
20.1.5.3 Trigger delay
During running-in, it is the standard position for cool mode. During emergency operating, by indoor to