Haier HSU-09HSA03/R2(DB) Air Conditioner User Manual


 
Haier air conditioner Edition: 20070116
-28-
measure standard position for enter cool /heat mode.
When operate starting, alarming to keep current position.
Received ventilated direction command delay 1s processing
Setting position range
Cool/dry: Pulse scope 45 degree
Heat: Pulse scope 60degree
During operating in closed cycle, it will move into open direction.
Swing-blade operating stop, keep the last output phase of excitation (1 phase); when unit operating
stop (all close), all of 4 phase close.
In the set range, back and forth move, the acting is foreign to ON/OFF of temperature sensor.
Cool/dry: Pulse scope 45degree.
Heat: Pulse scope 60degree.
At the both points waiting for 0.5s to return.
Received signal of stop operating or change direction, cancel swing mode.
During swing, appears alarm, the swing will continues.
During start operating, confirm adjustment position that is foreign to on/off of temperature sensor
When stop, move from current position to full close.
When switch mode, based on the position of panel send.
Under fixed position mode, alarm position keeps in the current position.
During heat swing, when switch to cool mode by the received signal, its acting position based on
indicator of remote control.
Adjust position based on the received contents, no delay 1s.
Up/down swing˖
Full off swing angle in cool˄60º˅
Position 1(cool normal positionˈmake an angle
of 10º with horizontal)
Position 2 ˄ make an angle of 25º with
horizontal)
Position 3 ˄ make an angle of 40º with
horizontal)
Position 4˄make an angle of 55º with horizontal) swing angle
in heat˄45º˅
Full opening position 5˄normal position in heat modeˈmake an angle of
70ºwith horizontal)
Reference position
Swing angle in the cool and dry mode˖45°
Swing angle in the heat mode ˖60°