Haier HSU-09HSA03/R2(DB) Air Conditioner User Manual


 
Haier air conditioner Edition: 20070116
-13-
Controlling table in the identity area˖
Temperature change area
AB C D E F G H
Heat FQUP(2Hz) FQUP(2Hz) FQUP(2Hz) FQUP(1Hz) FQUP(1Hz)
Cool and dry FQUP(2Hz) FQUP(2Hz) FQUP(2Hz) FQUP(1Hz) FQUP(1Hz)
FQUPH˖2Hz˗ FQUPL˖1Hz
2.4.8 Air capacity decision when Air capacity is running automatically.
When air capacity is running automatically, based on temperature adjusting sections, you shift the
switch for air capacity, namely, enhanced, middle, and weak.
When air capacity is running automatically, shown following air capacity table.
H---High M----Middle L---Low
Temperature adjustment section
ABCDE FGHI
Heat H H H H H M LLSL
O
Cool H H H M M LLL
Dry H M M M L L SLO SL
O
2.5 Defrost
When the high load precaution control operating, the priority is precaution control operating.
Compressor is not off.
During the heat-making operation, communication of outdoor unit will deliver defrosting signal (I21=10),
indoor unit will be based on defrosting controlling. It will continue until communication of outdoor unit
delivers defrosting released signal (I21=01), indoor unit will be on heat-making operation directly. Air
capacity will be of under the temperature controlling section of heat making.
2.6 Air capacity limited
During compressor operating, when the maximum speed of indoor fan be set middle or low speed, the
upper limit of indication frequency shown respectively as following:
Frequency number of air capacity limit table:
Limiting frequency variable Limiting frequency
Air capacity middle limit FQLIMMD 90Hz
Air capacity low limit FQLIMLO 52Hz
Upper and down limit of fresh
air capacity frequency
FUPHEAL 30Hz
Estimate the limiting frequency condition in heat mode; first, estimate it whether is the limiting
frequency condition of set low fan or health fan. If there have set low fan, health fan or both of them, to