Haier HSU-09HS03/R2DB Air Conditioner User Manual


 
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Fixing of outdoor unit
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Fix the unit to concrete or block with bolts ( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
Indoor Unit Outdoor Unit
Place, where a distance marked is available as illustrated
in the above figure.
Place, possible to bear the unit, where vibration and noise are
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place where the distance of more than 1m from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
Place, where cold air can be spread in a room entirely.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Place, possible to drain easily, where piping can be connected with the
outdoor unit.
Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
inlet and outlet of the unit are not disturbed.
Place, which is less affected by rain or direct sunlight and is
sufficiently ventilated.
Selection of Installation Place
Power Source
Selection of Pipe
The thickness of the pipe must be 0.8mm at least.
To this unit, both liquid and gas pipes shall be insulated
as they become low temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
Liquid pipe( )
Gas pipe( )
For 07,09 For 12
6.35mm (1/4")
9.52mm (3/8")
6.35mm (1/4")
12.7mm (1/2")
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
58
Model:
HSU-12HS03/R2(DB)
HSU-09HS03/R2(DB)Domestic Air Conditioner