Haier AU84NATEAA Air Conditioner User Manual


 
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Cooling
Heating
Indoor
Indoor
Outdoor
Outdoor
Maximum:
Minimum:
Maximum:
Minimum:
Maximum:
Minimum:
Maximum:
Minimum:
D.B / W.B
D.B / W.B
D.B / W.B
D.B / W.B
D.B / W.B
D.B
D.B
D.B
32 C / 23 C
18 C / 14 C
43 C / 26 C
15 C
27 C
15 C
24 C / 18 C
-7 C / -8 C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse o
n indoor unit PC board is broken, please change it with the type of T. 3.15A /250V.
If the fuse on
outdoor unit PC board is broken, please change it with the type of T. 6.3A /250V.
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided.
The power cable should be 5G 6.0mm
2
.
The connecting cable should be 4G 1.5mm
2
.
All the cables shall have got the European authentication certificate. During installation, when the connecting cables
break off, it must be assured that the grouding wire is the last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no
less
than 3mm.
7. The indoor unit installation height is at least 2.5m.
Installation and maintenance must be meet the local installation and
maintenance instructions and should operate by the
experienced special installation and maintenance technicians.
Otherwise we dont take any duty of the units damage or
injure to the person caused by improper operation.
NOTE:
1.The sharp edges and corners and coil surface have the danger to injury.
Please avoid of them.
2.Its very danger to remove the units and power supply wire, because it can cause injury and death. Cut off all the power
supply before
maintenance.
WARNING!
Safety Precautions
5