Test Run
Once the assembly is complete, test run your
downdraft table to make sure it runs properly and
verify safety features are in working order.
If, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review the
Troubleshooting on Page 20.
If you still cannot remedy a problem, contact our
Tech Support at (570) 546-9663 for assistance.
To test run the downdraft table:
1. Ensure that anyone in the vicinity of the
downdraft table, including yourself, is wear
-
ing safety glasses.
2. Make sure you have read the safety instruc-
tions at the beginning of the manual and that
the machine is set up properly.
3. Connect EACH motor to a dedicated 110V
circuit (see CIRCUIT REQUIREMENTS
,
Page 8).
4. Flip both paddle switches up to turn the
downdraft table
ON. Make sure that your
hand stays poised over the switches in case
you need to quickly turn the machine
OFF.
—When operating correctly, the machine
runs smoothly with little or no vibration or
rubbing noises.
Investigate and correct strange or unusual
noises or vibrations before operating the
machine further. Always disconnect the
machine from power before investigating
or correcting potential problems.
5. Turn the downdraft table OFF.
6. Remove the safety keys (Figure 12) and
attempt to turn the machine
ON.
—If the machine starts, stop it. The switch
disabling feature is not working. This safety
feature must work properly before proceed
-
ing. Call Tech Support for help.
—If the machine does not start, the switch
disabling feature is working.