Installation
309967C 9
Models 246914, 246917, 253387 and 253390
(FIG. 5 and FIG. 4)
1. Remove the cover from the pail, and scoop the
lubricant from the center to the sides of the pail to
make its surface concave.
2. Center the follow plate (5) in the pail opening. Press
the follow plate firmly downward and rotate it over
the lubricant surface to eliminate air pockets and
prevent channeling.
3. Place the cover (4) on the pail and tighten the
thumbscrews (A).
4. Install shim (11) on top of cover. Insert the pump
riser tube through the top of the shim (11) and cover
(4). Lower the pump until it rests on the shim and
cover.
5. Connect the swivel adapter to the pump fluid outlet.
Connect fluid hose (3c) to the swivel adapter. Con-
nect a suitable dispense valve.
6. Connect the swivel adapter to the pump air inlet or
air regulator (9b), whichever is applicable. Connect
the air hose (3a) to the swivel. Connect the air hose
to the air accessories.
FIG. 4
Model 253390 shown
3a
5
4
9b
3c
11
FIG. 5
8729
Model 253387
5
A
4
9b
3a
3c
11